Weeping Building Parts: What's All The Fuss About? - 2004-04-20

In the course of a home inspection, the inspector is looking at many components that are supposed to weep(1).

"Weep holes," as they are called in the trades, are openings that should be found at the base of all exterior siding -- including stucco, wood and composite siding, and brick veneer -- to drain away moisture that gets behind the exterior finish. Even when present, landscape grading and soil that is not held below the base of these sidings or veneer can block the weeping and can trap moisture behind the exterior finish.

The absence of these weep holes is what trapped moisture behind the EIFS (Exterior Insulated Finish System) stucco products of the 1980's and 1990's over which many class action lawsuits have been filed. The trapped water rotted away the framing behind the EIFS in as little as three years in one subdivision in North Carolina.

Another place weep holes are observed is at aluminum windows. The lower track of these windows is supposed to have weep holes facing out to direct moisture (from rain or condensation) that gets inside the track to the exterior. It is surprising how many times I have seen windows (original installations, but particularly replacement windows) installed backwards with the weep holes facing the interior of the house and even upside down with the weep holes on the top of the window.

Anywhere that condensation can occur, weeping drains are necessary. That's why a furnace with air conditioning should have a condensate drain plus a collection overflow pan under the unit with an overflow drain -- both pipes running to the exterior.

Related Article...

3082 - Many people in this country try to protect themselves and their communities by participating in local hearings. This could be town hall meetings, planning board meetings, environmental commission meetings, and just about anything else in which the public has a right to attend and participate. Often public debates turn into David vs. Goliath struggles where David is represented by the everyday person and Goliath consists of some big business developer or applicant. Obviously, there are differences in spending ability, including the ability to hire attorneys for the exclusive purpose of harassing those persons who are doing nothing more then attempting to exercise their rights to be heard. Harassive lawsuits such as these, designed simply to deter citizens from being heard, are called SLAPP suits. This stands for Strategic Lawsuits Against Public Participation. In essence, they are designed to SLAPP down the opposition. Most SLAPP suits are baseless and legally empty but they do have their intended affect because people are afraid of being sued. Even a lawsuit that is ultimately unsuccessful can scare citizens away from exercising their rights or performing their duty to participate in democracy. Read this Nemmar Real Estate Training article at Laws, Lawyers, Deeds, Building Codes, Zoning

 

Very often ceiling stains are NOT roof leaks, but condensate stains. Homeowners will occasionally install a new roof to address these "leaks" which turn out to be dripping from condensate of the air conditioning evaporative coil at the furnace located in the attic.

Condensation also occurs in the attic on cold surfaces during the winter months. Metal pipes and framing anchors are common sources from which I have seen evidence that they were dripping onto the ceiling below. Condensate drips also occur in summer months on uninsulated A/C lines in the attic and poorly drained evaporative coils (as in the case above).

Weeping holes are also critical at retaining walls. At the base of any wall designed to retain soil behind it, the most important issue is what to do with the weight of water that accumulates there. The first sign of a failing retaining wall is efflorescence caused by water leaching through the wall. The simple solutions are either weep holes or a footing french-drain behind the wall that drains to daylight.

The footing drain is best because it is less likely to silt-up. Weep holes installed at the base of a retaining wall must be protected from silt, or very quickly (three or four years) they will become clogged. This is particularly true of the weep holes designed into masonry walls by leaving out mortar at vertical joints at the base of the wall.

Unless a home inspector is looking for the failure of weeping components, s/he is probably not well trained. To determine professionalism, try asking your prospective home inspector if his/her report addresses "weeping."

(1)Source: Uniform Home Inspector's Code BookTM