Use the House illustrations Index pages to find specific images. For example, if you would like to find illustration images of "electrical wires", you could use the find feature of your web browser to search for "electrical" or "wires" on the House illustrations Index pages. Then you can use the House Illustration navigation menus for the specific category to find and view the image. Use the "Sort Gallery By" links above the illustrations to sort in ascending/descending order. You can also type the image description text and-or the image four-digit ID number in our site Search box to find the specific category for that exact house illustration image (A/C-Heat Pumps, Electrical, Exterior, Heating, Insulation, Interior, Plumbing, Roofing, Structure).

Related Article...

5009 - The dog and I have a daily obligation -- we walk about a mile and a half each morning, mostly through woods and country-like roads by the house. This is good exercise for us both, as well as a way to count the deer, fox and raccoons that live nearby. Alas, our morning walks have been interrupted during the past few days as a result of Hurricane Isabel. Not a nice lady, Isabel downed trees and knocked out power lines in a big way. As a result, electrical service in Baghdad has been more reliable then what we have locally -- and what we have locally is just a few miles from the White House and Capitol Hill. You know what's going to happen next -- insurance companies will be flooded with claims, mostly with good reason. But given recent trends, homeowners might want to think carefully before making such calls. To understand the concern, consider that in the Washington area we have an arsonist who has apparently struck more than 25 times in recent months. One victim explained how her home was set on fire and so she did what anyone else would do: she filed an insurance claim. As I understood the story on TV, the claim will be paid -- but her policy has been canceled because the owner had a prior claim several years ago. Read this Nemmar Real Estate Training article at Insurance, Taxes

 

Click to go to section: G - H

 

G
Gabion Retaining Walls 1930
Gable
----- Details 1706
----- Overhang Less than 16 Inches 0421
----- Overhang More than 16 Inches 0422
----- Roof 0002
----- Wall for Roof 0420
Galvanized Steel and Aluminum Gutter - Identifying 1896
Galvanized Steel Pipe in Plumbing System 1504
Gambrel and Mansard Roofs - Venting 1348
Gambrel Roof 0002
Gaps under Wall Sill 0282
Garage
----- and Carport 1825
----- Below-grade - Drains 1863
----- Combustible Insulation Exposed 1858
----- Door Openers 1867 - 1871
----- Door Problems 1866
----- Door Types 1865
----- Electrical Outlets - 18 Inches off the Floor 0622
----- Fire and Gas Proofing 1855
----- Floor Drainage 1860
----- Floor Structural 1859
----- Heating Ductwork 1856
----- Man Door 1857, 2066
----- Settlement 0355
----- Slab
----- ----- on Disturbed Soil 1861
----- ----- Settling 1861
----- ----- with Water Heater 1872
Garbage Disposal
----- Switches 0626
----- Wiring 0627
Gas Appliance
----- Connectors - Flexible 0721
----- Two on One Flue 0993
----- with Improper Sidewall Venting 0802
Gas Burner 0737-0747
----- Continuous Pilot Light 0744
----- Crossover Igniter 0740
----- Monoport 0738
----- Natural Draft 0731
----- Relighting Pilot Light 0745
----- Scorching 0746
Gas Fired Floor Furnace
----- Clearances 0160
----- Inspection Cap Missing or Damaged 1161
Gas Fired Space Heater
----- Combustible Clearances 1162
----- Unvented 1164
Gas Fired Wall Furnace 1153
----- Clearances from Combustibles 1154
----- Unvented 1159
Gas Fireplace
----- Combustible Clearances 1168
----- Direct Vent 1167
----- Location Restrictions 1166
----- not Fixed Open 1165
Gas Furnace
----- Automatic Vent Damper 0812
----- Chimney-Vent Connections 0772
----- Condensing 0803-0816
----- High Efficiency
----- ----- Duct Sizes 0811
----- ----- Maximizing Temperature Differences 0805
----- ----- Venting 0806
----- Horizontal 0754
----- Mid Efficiency 0798-0802
----- Sidewall Venting 0815
----- Vent Connector
----- ----- Length 0768
----- ----- Size 0771
----- ----- Slope 0767
----- ----- Support 0769
Gas Igniters for Fireplaces 1095
Gas Meter
----- Location For Water Heater 1570
----- Poor Location 0719
Gas Piping
----- Connections with Teflon Tape 0722
----- Drip Leg 0727
----- ----- on Water Heater 1572
----- Electric Grounding 0548, 0725
----- Flexible Copper Tubing 0723
----- Support 0026
----- Support for Water Heater 1571
----- Terminology 0720
Gas Proofing Garages 1855
Gas Regulator - Ice 0718
Gas Shut Off Valve 0724
----- Gas Shut Off Valve for Water Heater 1573
Gas Supply to Burner 0739
Gas Water Heater 1562
Gaskets - Sill 1334
Gaskets for Electrical Boxes 1335
Gate Valve for Plumbing 1535
Georgian Style 1725
Glass Doors for Fireplaces 1093
Glass
----- Location for Windows 2044
----- Low-E 2043
----- Spacing in Windows 2045
Glazing
----- Compound (Putty) 1815
----- Sloped 2048
----- Types for Windows 2036
Globe Valve for Plumbing 1534
Gothic Revival Style Home 1730
Gothic Windows 1719
Grade Clearance for Siding Inadequate 1748
Grading - Exterior 1880 - 1892
Graduated Slate Roof 0031
Gravel Erosion on Flat Roofs 0094
Gravity Furnace 0710
Greek Revival Style Home 1724
Grill in Furnace Room - Return 0796
Grills, Diffusers and Supply Air Registers 0790
Ground and Neutral Wires - Electrical Path 0547
Ground Source Heat Pump
----- Horizontal Closed Loop 1276
----- Vertical Closed Loop 1286
Ground Wires - Location 0551
Ground Wires let Fuses Blow 0546
Ground-Fault Circuit Interrupter 0614
Ground-Fault Interrupter Electrical 0614
Ground-Fault Interrupters Protect Ordinary Outlets Downstream 0615
Grounding Equipment - Electrical 0533
Grounding of Electric Service Box 0555
Grounding the Gas Piping 0548, 0725
Guards and Handrails
----- for Exterior Stairs 1833
----- for Stairs 2029
Gutter and Downspout 1893 - 1920
----- Installation 1902
Gutter
----- Attachment Methods 1900
----- Common Leakage Causes 1898
----- Discharging onto Roof 0003
----- Excess Shingle Overhang 1897
----- Identifying Aluminum and Galvanized Steel 1896
----- Integral 1894
----- ----- Repairs 1899
----- ----- with Screen 1901
----- Yankee 1895
Gypsum Lath vs. Drywall 2009

H
Half Woven Valley 0063
Half-timbering 1711
Handrail
----- and Guards for Exterior Stairs 1833
----- and Guards for Stairs 2029
----- Design 1834
----- or Guards too Low 1836
----- Support 2033
Handsplit and Re-sawn Shakes 0020
Hangers for Copper Plumbing Pipe 1544
Hardboard Siding 1794
Hartford Loop
----- and Equalizer Details for Steam Heat 1122
----- and Equalizer for Steam Heat 1117
----- Close Nipple Missing on Steam Heat 1123
----- on Steam Heating 1103
Hatch - Attic Access 1358
H-clips for Roof Sheathing 0445
Head Flashing Details on Chimney Flashing 68
Headlap on Asphalt Shingles 0011, 0013
Hearth
----- Extension Dimensions for Fireplaces 1069
----- Extension Forming Boards - Removed 1072
----- Extensions for Factory Built Fireplaces 1071
----- Materials 1067
----- for Fireplaces - Raised 1070
Heartwood 0019
Heat
----- Circulators for Fireplaces 1094
----- Content of Various Fuels 1012
----- How It Is Generated 0700
----- People Releasing 1303
Heat Exchanger 0748-0752
----- and Hot Water Boilers 0850
----- Components for Pulse Furnace 0810
----- Copper Tube in Boilers 0851
----- for Wood Furnaces 1020
----- Heat Flow 0748
----- HRV and ERV 1353
----- in High Efficiency Gas Furnaces - Long 0803
----- on Furnace with Humidifier Above 0788
----- with Heat Pump Coil Upstream 0752
Heat Pump
----- All Electric 1274
----- Balance Point 1273
----- Bivalent 1287
----- Co-efficient of Performance 1272
----- Coil Upstream of Furnace Heat Exchangers 0752
----- Condenser Coil 1270
----- Defrost Cycle 1280
----- Evaporator Coil 1269
----- Ground Source
----- ----- Horizontal Closed Loop 1276
----- ----- Vertical Closed Loop 1286
----- Outdoor Coil Location 1281
----- H Principles 1268
----- Schematic - Summer Mode 1271
----- Testing Back Up Heat 1283
----- Triple Split System 1278
----- Two Expansion Devices 1279
----- Water Source - Open Loop 1275
Heat Recovery Ventilator 1323
----- Cold-side Ducts not Insulated 1397
----- (Basic Components) 1352
----- Core Missing or Dirty 1404
----- Defrost Control 1357
----- Exhaust Grill Locations 1400
----- Filters and Condensate Drains 1356
----- Filters Dirty or Missing 1403
----- Flow Collars and Balancing Dampers 1401
----- Furnace Duct Connection 1399
----- Intake and Exhaust Locations 1398
----- not Interlocked with Furnace Fan 1402
----- Trap in Condensate Drain 1405
Heat Registers in Basements 0795
Heat Shield or Flame Rollout Shield 0747
Heat Transfer
----- Methods of 0713
----- at the Inside Coil - Air Conditioning 1201
----- from Inside to Outside During Air Conditioning 1200
----- Mechanisms 1302
Heaters - Wood Space 1034-1059
Heating Cables to Prevent Ice Damning 0006
Heating Distribution System - Forced Air 0775-0797
Heating Ductwork in Garages 1856
Heating Requirements for Electric Heat 1135
Heating System - House Air Flow 0711
Heatlamp - Poor locations 0609
Heaving
----- Frost - Evidence 0202
----- Frost - Unheated Houses 0205
----- Frost - Unlikely 0204
----- of Deck Piers 0243
----- of Footings due to Frost 0223
----- Sources 0236
Height
----- of Chimney 0977
----- of Chimney above Appliance 0978
----- of Metal Chimney 1006
----- of Adjacent Metal Chimneys 1009
Helical Anchors 0226
High and Low Returns for Forced Air Systems 0792
High Efficiency Furnace
----- and Duct Size 0811
----- Condensation 0804
----- Have Long Heat Exchangers 0803
----- Inspecting 0813
----- Maximizing Temperature Differences 0805
----- Safety Devices 0808
----- Venting 0806
High Temperature Limit Switch on Boiler 0855
High Water Table 2074
High-hat Lights in Insulated Ceilings 0607
Hinged Pillars Affect Roof Structure 1852
Hip and Valley Rafter 0415
Hip Roof 0002
Hole in the Roof - Before Chimneys 0706
Holes and Notches
----- in Beams 0301
----- in Joists 0326
----- in Top Plates of Bearing Walls 0369
Hollow Concrete Floors 2006
Hollow Masonry - Channels must be Vertical 0365
Homes Built with Holes for Chimneys 0707
Honeycombing in Concrete 0269
Hopper and Awning Windows 1716
Horizontal Cracks
----- on Foundations 0244
----- and Movement - Three Possibilities 0246
Horizontal Gas Furnace 0754
Horizontal Projection of Rafters Determine Span 0416
Horizontal Wood Siding 1779
Hot Climate Moisture Control 1319
Hot Climates - Controlling Moisture 1325
Hot Surface Ignition 0799
Hot Water
----- Radiant Heat 0898
----- Boiler
----- ----- Copper Tube Heat Exchanger 0851
----- ----- Heat Exchanger 0850
----- ----- How It Works 0846
----- Heating
----- ----- Balancing Methods 0880
----- ----- Cast Iron Baseboard 0893
----- ----- Circulating Pump 0885
----- ----- Closed System 0875
----- ----- Convectors 0891
----- ----- Conventional Expansion Tank 0883
----- ----- Covering Radiators Reduces Efficiency 0890
----- ----- Diaphragm Tank 0884
----- ----- Expansion Tank - Overflow Pipe 0882
----- ----- Expansion Tank Water Levels 0881
----- ----- Extending 0889
----- ----- Finned Tube Baseboard 0892
----- ----- Mixing Systems 0894
----- ----- One Pipe System 0877
----- ----- Open System 0874
----- ----- Pipe Corrosion 0888
----- ----- Radiant with Water Blender 0899
----- ----- Radiator Covers 0848
----- ----- Radiator Valve Leaks 0896
----- ----- Radiators On Ceilings 0895
----- ----- with Bypass Loop 0903
----- ----- with Series Loop 0876
----- ----- with Sidearm Heater 0901
----- ----- with Tankless Coil 0900
----- ----- with Two Pipe System (Reverse Return) 0879
House Air Changes with Exhaust System Components 1350
House Air Flow in a Forced Air Heating System 0711
House Fan - Whole 1266
----- Inadequate Attic Venting 1267
House Structure - Overview 0200
House Ventilation - Three Approaches 1349
Household Wiring in Parallel 0511
Housewrap vs. Building Paper 1333
How Hot Water Boilers Work 0846
HRV
----- Basic Components 1352
----- and ERV Heat Exchangers 1353
----- Cold Side Ducts not Insulated 1397
----- Components 1354
----- Core Missing or Dirty 1404
----- Defrost Control 1357
----- Exhaust Grill Locations 1400
----- Filter and Condensate Drains 1356
----- Filter Dirty or Missing 1403
----- Flow Collars and Balancing Dampers 1401
----- Furnace Duct Connection 1399
----- Intake and Exhaust Locations 1355, 1398
----- not Interlocked with Furnace Fan 1402
----- Trap in Condensate Drain 1405
Humidifier
----- above Heat Exchanger 0788
----- Air Flow 0787
----- Dampers Closed - Air Conditioning 1259
----- Drum-Type 0785
----- Trickle Type 0786
----- on Forced Air Heating Systems 0785-0788
Hydronic Heating
----- Balancing Methods 0880
----- Circulating Pump 0885
----- Closed System 0875
----- Convectors 0891
----- Conventional Expansion Tank 0883
----- Covering Radiators Reduces Efficiency 0890
----- Diaphragm Tank 0884
----- Expansion Tank - Overflow Pipe 0882
----- Expansion Tank Water Levels 0881
----- Extending System 0889
----- Finned Tube Baseboard 0892
----- Mixing Systems 0894
----- One Pipe System 0877
----- Open System 0874
----- Pipe Corrosion 0888
----- Radiant 0898
----- Radiant with Water Blender 0899
----- Radiators on Ceilings 0895
----- Two Pipe System (Direct Return) 0878
----- Two Pipe System (Reverse Return) 0879
----- with Bypass Loop 0903
----- with Sidearm Heater 0901
----- with Tankless Coil 0900

Discuss this article

Real Estate From A to Z  -  Nemmar Real Estate Training. House Exterior Interior Structure Roofing Plumbing Insulation Heating Electrical Air Conditioning Construction Repair Home Improvement Renovation Home Inspection Appraisal Market Value

Nemmar Real Estate Training
Nemmar Business and Computer Consulting