1225 Excess Electric Current Draw Beyond Standards - Air Conditioning - Compressor
 
1225 Excess Electric Current Draw Beyond Standards - Air Conditioning - Compressor -

Image Text: Using an amp-meter, measure the draw of the air conditioner at the electrical panel (be sure to subtract the amperage related to the condenser fan) > the measured amperage should be 60% to 90% of the RATED LOAD AMPERAGE (RLA) indicated on the data plate > if the current draw is at or above the RLA, the compressor may be near the end of its life > distribution panel > STOVE > 15 amp fuse > neutral bus bar > black wire > red wire > To A/C > the current can be measured at either the red or black wire > amp meter >neutral wire

Powered by Phoca Gallery

AIR CONDITIONING and HEAT PUMPS, Air Conditioning Capacity, Compressor, Condenser Coil (Outdoor Coil), Evaporator Coil (Indoor Coil), Condensate System, Refrigerant, Condenser Fan (Outdoor Fan), Evaporator Fan (Indoor Fan), Duct System, Thermostats, Life Expectancy, Evaporative Coolers, Whole House Fans, Heat Pumps, Heat Pumps in Theory, Heat Pumps in Practice

­