0546 Ground Wires Let Fuses Blow - Electrical Electricity - System Grounding
 
0546 Ground Wires Let Fuses Blow - Electrical Electricity - System Grounding -

Image Text: Distribution panel > stove > main bus bars > ground wire > panel grounded through metal conduit from service entrance > 15 amp fuse > black (hot) wire shorting against panel box > household circuit > neutral wire > neutral bus bar > since the panel is grounded, the black wire shorting against the metal sides allows the electricity to flow easily to ground (very little resistance) - the resulting high current flow immediately blows the fuse (deactivating the circuit) > if the panel were not grounded properly and someone touched the metal box, electricity would flow through the person (enough to kill them), but possibly not enough to blow the fuse

Powered by Phoca Gallery

Image courtesy of Carson Dunlop. To purchase images, go to CarsonDunlop

ELECTRICAL, Service Drop and Service Entrance, Basics of Electricity, Service Drops, Service Entrance Wires, Service Size, Service Box, Grounding and Panels, Service Boxes, System Grounding, Distribution Panels, Distribution System, Branch Circuit Wiring (Distribution Wiring), Knob-and-Tube Wiring, Aluminum Wire, Lights, Outlets and Switches

­