Back To Category
1123 Hartford Loop Close Nipple Missing - Heating - Steam Boiler Problems
 
1123 Hartford Loop Close Nipple Missing - Heating - Steam Boiler Problems -

Image Text: Cross section > boiler water line > water hammer > steam bubbles > equalizer pipe > hot boiler water > close nipple > 2 inches to 3 inches > Hartford Loop > cool condensate water > as the cool condensate water comes out of the Hartford Loop, the steam bubbles in the equalizer condense > the collapsing steam bubbles create a vacuum that accelerates the condensate water into the back of the "T" - creating water hammer > by using a close nipple, the horizontal leg of the Hartford Loop is made as short as possible - minimizing the horizontal momentum of the water and, therefore, the water hammer

Powered by Phoca Gallery

HEATING, Furnaces Gas and Oil, Heat Transfer, Gas Piping and Meters, Combustion Air, Gas Burners, Heat Exchangers, Furnace Cabinets, Fan/Limit Switches, Thermostats, Venting Gas Furnaces, Distribution System, Blowers, Air Filters and Cleaners, Humidifiers, Duct Systems, Registers and Grills, Mid Efficiency Furnaces, Condensing Furnaces, Gravity Furnaces, Combination Furnaces, Oil Furnaces, , Hot Water Boilers (Hydronic Heating), Heat Exchangers, Controls, Distribution Systems, Pulse Combustion, Chimneys, Masonry Chimneys, Metal Chimneys or Vents, Wood Heating Systems, Furnaces and Boilers, Wood Stove (Space Heaters), Wood Burning Fireplaces, Steam Heating Systems, Common Steam Systems, Steam Controls, Components and Problems, Electric Heating Systems, Space Heaters, Electric Furnaces, Electric Boilers, Radiant Heating, Wall and Floor Furnaces, Room Heaters and Gas Fireplaces, Wall Furnaces, Floor Furnaces, Room Heaters, Gas Fireplaces and Gas Logs

­