Back To Category
0267 Pilaster Pulling Away from Wall - Structure Structural Foundation - Problems
 
0267 Pilaster Pulling Away from Wall - Structure Structural Foundation - Problems -

Image Text: Cross section > bulging and cracked foundation wall > topsoil > backfill > horizontal crack > use a plumb bob or mason's level to check to see if the pilaster is plumb > wall framing > floor framing > pilaster > a retrofit pilaster may pull away from the foundation wall because: A: the pilaster is poorly installed > B: the foundation wall is continuing to lean or bow and is pushing the pilaster away > C: the footing is inadequately sized or missing

Powered by Phoca Gallery

Image courtesy of Carson Dunlop. To purchase images, go to CarsonDunlop

STRUCTURE, Footings and Foundations, Description, Problems, Floors, Sills, Columns, Beams, Joists, Subflooring, Concrete Floor Slabs, Walls, Solid Masonry Walls, Wood Frame Walls, Masonry Veneer Walls, Arches and Lintels, Roof Framing, Rafters, Roof Joists and Ceiling Joists, Collar Ties, Knee Walls and Purlins, Trusses, Wood I Joists, Sheathing

­