Back To Category
0391 Brick Veneer Wall Masonry Tie Detail - Wall Systems - Masonry Veneer Walls
 
0391 Brick Veneer Wall Masonry Tie Detail - Wall Systems - Masonry Veneer Walls -

Image Text: Stud > sheathing > sheathing paper > masonry veneer tie > 1 inch gap minimum > spacing of veneer ties > maximum vertical spacing > 16 inches > 20 inches > 24 inches > maximum horizontal spacing > 32 inches > 24 inches > 16 inches > Note: veneer ties are nailed through sheathing into studs

Powered by Phoca Gallery

Image courtesy of Carson Dunlop. To purchase images, go to CarsonDunlop

STRUCTURE, Footings and Foundations, Description, Problems, Floors, Sills, Columns, Beams, Joists, Subflooring, Concrete Floor Slabs, Walls, Solid Masonry Walls, Wood Frame Walls, Masonry Veneer Walls, Arches and Lintels, Roof Framing, Rafters, Roof Joists and Ceiling Joists, Collar Ties, Knee Walls and Purlins, Trusses, Wood I Joists, Sheathing

­